CLASS 1
DIVISION 2
SOLAR POWER SYSTEMS

Off-grid power systems engineered for hazardous zones. Built for operation in areas with potential gas or vapor exposure – like well sites, pipeline valve controls, and data communication equipment.

Factory Assembled

Every system is built and tested in our Colorado facility using Class 1 Div 2-rated components. Panels, enclosures, and wiring are integrated in-house to reduce fieldwork and meet hazardous location standards.

Quick Deployment

Skid-mounted or container-based systems that can be easily moved and installed with light-duty equipment. No on-site assembly or complex setup required.

Explosion Proof

Includes gas-safe charge controllers, sealed batteries, NEMA enclosures, and IP-rated junctions. Designed for use in areas where flammable gases may be present during normal operation or failure conditions.

Class 1 Division 2 Solar Power Systems for Hazardous Locations

Reliable Power Where It Matters Most

In Class 1 Division 2 zones—like pipelines, production sites, and chemical storage areas—unexpected releases of hazardous gases can occur. Only certified systems are acceptable. SolarSet builds Class 1 Division 2 solar power systems specifically for hazardous locations. These systems are rugged, easy to deploy, and built for the realities of fieldwork.

Whether you’re powering cathodic protection, instrumentation at a wellhead, or a telemetry unit down the line, our systems are built to deliver dependable off-grid power where safety matters.

What Does Class 1 Division 2 Really Mean?

Class 1 Division 2 locations are areas where explosive gases or vapors aren’t typically present, but could be during equipment failures, leaks, or maintenance. Any power equipment in these zones needs to be built to prevent ignition.

Our systems use certified components designed for this exact environment:

  • Class 1 Div 2 charge controllers
  • IP65-rated junction boxes
  • NEMA-rated enclosures
  • Pre-wired solar arrays and sealed battery systems

Built to code. Field-ready. No added complexity.

SolarSet Systems: Challenger, Mesa, and Long Trek

Challenger

For long-term, high-output needs in harsh locations. Skid-mounted with extended battery autonomy. Built for use at wellpads, RTUs, and tank farms.

Mesa

Foldable, compact, and fits inside a standard shipping container. Designed for fast deployment in remote or export scenarios where infrastructure is limited.

Long Trek

Lightweight and made for mobile crews or off-grid installs with rough access. Ideal for instrumentation and portable needs.

Each one supports Class 1 Division 2 applications and comes fully pre-wired, tested, and ready to drop in place.

Built by Engineers Who Know the Oilfield

Our systems are designed and assembled in collaboration with Power Zone Equipment, a company that’s been building custom pump and power systems for the oil and gas industry for over 25 years.

We share facilities, engineers, and the same approach to doing things right:

  • Industrial-grade quality control
  • Engineering experience with refinery and pipeline projects
  • Designs that work in real-world oilfield conditions

Common Applications

SolarSet systems are designed for use in Class 1 Div 2 zones. Common applications include:

  • Cathodic protection
  • SCADA and telemetry
  • Gas detection and flow monitoring
  • Remote wellhead power
  • Tank farm instrumentation
  • Offshore or coastal platforms

These systems often replace diesel gensets—cutting fuel costs and reducing maintenance trips.

What’s Inside the System?

Every SolarSet system includes:

  • Class 1 Div 2 rated solar panels built for industrial reliability
  • Class 1 Div 2 charge controllers with LVD and thermal protection
  • Sealed VRLA or gel batteries
  • UL/CSA-listed enclosures (NEMA 3R or 4X)
  • IP65-rated junction boxes with locking terminals

They ship fully assembled and labeled. No site-built wiring, no guesswork—just bolt it down and power up.

Why Use SolarSet?

  • Certified for Hazardous Locations: Built with Class 1 Div 2–rated components
  • Proven in the Field: Backed by Power Zone’s decades in oil and gas
  • Quick to Install: Pre-wired and tested in-house
  • Tough and Transportable: Skid-mounted

Get a Custom Quote

If you’re outfitting a remote wellpad, pipeline monitor, or tank battery, we can help spec the right system. We offer sizing and system design based on your location, load, and layout.

Get in touch—we’ll turn around a quote fast and get you what you need.

FREE CURBSIDE DELIVERY WITHIN 300 ROAD MILES FROM OUR FACTORY

  • This service assumes delivery is made on an easily accessible driveway or parking lot directly connected to a well-maintained public road. Setting the unit in place and anchoring the system are additional services, available in select locations only, and will be priced on a case-by-case basis.
  • If unit is to be unloaded on public property, formal proof of permission from the Authority Having Jurisdiction is needed prior to arrival. 
  • The buyer, or a representative of the buyer, must be on-site to accept the system.

*Limitations Apply

Contact us for more information

719-759-5100
sales@solarset.com
46920 County Road E.
Center, CO. 81125